AS9100 & DFARS 252.225-7009 Technical Receiving Guide
Master Receiving Checklist: AS9100 12-Point Receiving Inspection & DFARS 252.225-7009 Specialty Metals Checklist →

Aerospace & Defense Alloy MTR Receiving Inspection Library

Editorial & Copyright Hygiene Notice: These technical receiving guides are written for AS9100 Rev D, ISO 9001, ISO 13485, and defense-subtier Quality Managers and Receiving Inspectors. All regulatory citations reference public US federal statutes (10 U.S.C. § 4863, DFARS 252.225-7009, DFARS 225.872-1). These guides do not reproduce copyrighted ASTM, SAE/AMS, or ASME specification tables; inspectors must always verify actual ladle/product values against their facility's licensed specification revision, Purchase Order (PO) flow-downs, and the specification min/max rows printed on the mill certificate. Final material release remains the sole responsibility of authorized human Quality Assurance personnel.

Raw-material receiving inspection is where $25,000 scrap events and AS9100 Major Corrective Action Requests (CARs) are prevented in five minutes. Yet every alloy family carries distinct certification failure modes—from Condition A vs. H900 capability-test confusion on 17-4PH, to ppm-vs-percent interstitial Hydrogen/Oxygen traps on Ti-6Al-4V, to DFARS 252.225-7009 melt-country misunderstandings on 6061-T6 aluminum.

Select an alloy family below for a focused, receiving-dock-ready verification checklist, or launch the free interactive validator directly.


Instant Compliance Utility (Free, Zero Signup)


Alloy-Specific Receiving Inspection Guides

Alloy Family & Common DesignationsDFARS 252.225-7009 Specialty Metal?Primary Receiving Dock Traps CoveredTechnical Guide
17-4PH / Type 630 Stainless (UNS S17400; Aerospace Bar/Forging/Plate)YES (Steel >0.25% Cr/Ni/Cu/Nb)Solution-annealed (Cond A) capability tests mistaken for aged (H900/H1025) stock; Nb+Ta sum math; VAR/ESR Consumable Electrode remelt checksRead 17-4PH MTR Checklist →
Ti-6Al-4V Titanium (Grade 5 / Grade 23 ELI; UNS R56400 / R56401)YES (Titanium & Titanium Alloys)Foreign sponge/ingot melt vs. US rolling; interstitial O, N, C, H (ppm vs. wt% decimal shifts); Grade 5 vs. ELI confusion; beta transus & alpha-case notesRead Ti-6Al-4V MTR Checklist →
316 / 316L Dual-Certified Stainless (UNS S31600 / S31603)YES (Steel >0.25% Cr/Ni/Mo)Straight 316 carbon (>0.030%) accepted on welded 316L prints; distributor transcription typos (0.024% vs. 0.24%); Austria (225.872-1(b)) & non-qualifying melt trapsRead 316/316L MTR Checklist →
Alloy 718 / Nickel Superalloy (UNS N07718; Precipitation-Hardened)YES (Nickel Base >10% Alloying)Master Heat vs. Remelt Ingot vs. Heat-Treat Lot lineage breaks; Nb (Cb) + Ta combined reporting; solution-anneal (1700–1850°F vs. 1900°F+) & creep/rupture test checks; AS9102 Form 2 loggingRead Alloy 718 CMTR Guide →
6061-T6 & 7075-T651 Aluminum (UNS A96061 / A97075)EXEMPT from 252.225-7009 (Watch Buy American / TAA!)False vendor rejections over DFARS 252.225-7009 vs. real Buy American (252.225-7001) / TAA (252.225-7021) rules; stress-relieved temper (T6 vs. T651/T6511); eddy-current conductivity (% IACS) checksRead Aluminum MTR Checklist →

Across every alloy guide in this library, ProvaTrace recommends a clean, auditor-approved 3-Source Verification Protocol:

  1. Printed MTR Specification Min/Max Rows: Compare actual ladle/check heat results directly against the minimum and maximum requirement rows printed on the melting mill's EN 10204 Type 3.1 / 3.2 certificate (after normalizing MPa <-> ksi and ppm <-> %).
  2. Purchase Order & Shop Material Master Flow-Downs: Cross-check alloy grade, condition/temper, melt method (e.g., air melt vs. VAR/VIM-VAR), NDT level, and customer-specific engineering notes defined on your shop's PO.
  3. Public Federal Melt-Origin Statutes: Verify explicit Country of Melt (not merely rolling, finishing, or shipping location) on the original melting mill certificate against 10 U.S.C. § 4863 and the 28 reciprocal DFARS 225.872-1(a) Qualifying Countries whenever DFARS 252.225-7009 is flowed down.

Ready to Eliminate Manual MTR Highlighting & Filing?


Disclaimer: ProvaTrace provides deterministic document-extraction, unit-normalization, and clerical comparison software requiring authorized human QA inspector sign-off. Do not upload ITAR (22 CFR 120–130) or DoD CUI technical drawings.